Search results for "cortical bone"

showing 10 items of 69 documents

Long-term leisure time physical activity and properties of bone: A twin study

2009

Effects of physical activity on bone properties, when controlled for genetic effects, are not fully understood. We aimed to study the association between long-term leisure time physical activity (LTPA) and bone properties using twin pairs known to be discordant for leisure time physical activity for at least 30 yr. Volumetric BMD and geometric properties were measured at the tibia shaft and distal end using pQCT in 16 middle-aged (50-74 yr) same-sex twin pairs (seven monozygotic [MZ] and nine dizygotic [DZ] pairs) selected from a population-based cohort. Paired differences between active and inactive co-twins were studied. Active members of MZ twin pairs had larger cortical bone cross-secti…

AdultGerontologymedicine.medical_specialtyHistologyAdolescentBone densityPhysiologyEndocrinology Diabetes and MetabolismOsteoporosisPopulationLong boneLeisure timePhysical activityPhysical exercise030209 endocrinology & metabolismMotor ActivityCohort StudiesYoung Adult03 medical and health sciences0302 clinical medicineBone DensityInternal medicinemedicineHumansOrthopedics and Sports MedicineTibia030212 general & internal medicineeducationAged030304 developmental biology0303 health scienceseducation.field_of_studyTibiabusiness.industryMiddle Agedmedicine.diseaseTwin studyTerm (time)SurgeryCross-Sectional StudiesEndocrinologymedicine.anatomical_structureCortical boneTomography X-Ray ComputedbusinessBone
researchProduct

Marginal Bone Loss in Implants Placed in Grafted Maxillary Sinus

2013

Purpose The purpose of this study is to evaluate the vertical and horizontal graft bone resorption (GR) in grafted maxillary sinuses and the marginal bone loss (MBL) around implants placed in the sinuses with different prosthetic connections and to determine the effect of other clinical factors on these tissue responses at 6 and 18 months postloading. Material and Method A total of 254 implants were placed in 150 grafted maxillary sinuses of 101 patients (51.5% female) with mean age of 52.2 years (range, 32–82 years). GR and MBL measurements were made in implants placed with two different prosthetic connections (internal and external) at 6 and 18 months postloading. The complex samples gene…

Maxillary sinusbusiness.industryDentistryBone resorptionResorptionmedicine.anatomical_structureMedicineCortical boneImplantOral SurgerybusinessGeneral DentistryAbutment (dentistry)Sinus (anatomy)Dental alveolusClinical Implant Dentistry and Related Research
researchProduct

Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten

1997

PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…

musculoskeletal diseasesMaterials sciencemedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentmedicine.anatomical_structureNuclear magnetic resonanceSpinal fusionBone qualitymedicineRadiology Nuclear Medicine and imagingCortical boneDual x-ray absorptiometryQuantitative computed tomographyCadaveric spasmNuclear medicinebusinessCancellous boneFixation (histology)RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Association between low-frequency ultrasound and hip fractures - comparison with DXA-based BMD

2013

Background New methods for diagnosing osteoporosis and evaluating fracture risk are being developed. We aim to study the association between low-frequency (LF) axial transmission ultrasound and hip fracture risk in a population-based sample of older women. Methods The study population consisted of 490 community-dwelling women (78–82 years). Ultrasound velocity (VLF) at mid-tibia was measured in 2006 using a low-frequency scanning axial transmission device. Bone mineral density (BMD) at proximal femur measured using dual-energy x-ray absorptiometry (DXA) was used as the reference method. The fracture history of the participants was collected from December 1997 until the end of 2010. Lifestyl…

medicine.medical_specialtyBone densityCortical boneOsteoporosisPopulationDentistryRisk AssessmentHip fractureAbsorptiometry PhotonRheumatologyBone DensityPredictive Value of TestsRisk FactorsmedicineHumansOrthopedics and Sports MedicineProspective StudieseducationOsteoporosis PostmenopausalAgedUltrasonographyFemoral neckAged 80 and overBone mineralHip fractureeducation.field_of_studyTibiaFemur NeckHip Fracturesbusiness.industryOdds ratiomedicine.diseaseFractures Spontaneousmedicine.anatomical_structureSpeed of soundOsteoporosisFemaleRadiologybusinessRisk assessmentQuantitative ultrasoundFollow-Up StudiesResearch ArticleBMC Musculoskeletal Disorders
researchProduct

Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study

2007

Determination of cortical bone thickness is warranted, e.g., for assessing the level of endosteal resorption in osteoporosis or other bone pathologies. We have shown previously that the velocity of the fundamental antisymmetric (or flexural) guided wave, measured for bone phantoms and bones in vitro, correlates with the cortical thickness significantly better than those by other axial ultrasound methods. In addition, we have introduced an inversion scheme based on guided wave theory, group velocity filtering and 2-D fast Fourier transform, for determination of cortical thickness from the measured velocity of guided waves. In this study, the method was validated for tubular structures by usi…

Materials scienceAcoustics and UltrasonicsBiophysicsModels BiologicalRadius boneOpticsBone DensitymedicineHumansUltrasonicsRadiology Nuclear Medicine and imagingQuantitative computed tomographyPolyvinyl ChlorideUltrasonographyGuided wave testingRadiological and Ultrasound Technologymedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundReproducibility of ResultsRadiusmedicine.anatomical_structurePlate theoryCortical boneUltrasonic sensorTomographyTomography X-Ray ComputedbusinessBiomedical engineeringUltrasound in Medicine &amp; Biology
researchProduct

Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius

2008

Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-differ…

AdultMaleTime FactorsMaterials scienceAcoustics and UltrasonicsAcousticsModels BiologicalMotionYoung AdultOpticsArts and Humanities (miscellaneous)Image Interpretation Computer-AssistedmedicineHumansComputer SimulationTime domainDispersion (water waves)AgedUltrasonographyAged 80 and overGuided wave testingbusiness.industryUltrasoundBiomechanicsReproducibility of ResultsNumerical Analysis Computer-AssistedRadiusMiddle AgedRadiusmedicine.anatomical_structureConnective TissueFemaleUltrasonic sensorCortical bonebusinessThe Journal of the Acoustical Society of America
researchProduct

Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women

2009

The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…

musculoskeletal diseasesBone densityEndocrinology Diabetes and MetabolismBody Mass IndexFractures BoneAbsorptiometry PhotonBone DensityRisk FactorsmedicineAnimalsHumansOrthopedics and Sports MedicineTibiaAgedBone mineralOrthodonticsTibiaBody WeightBiomechanicsAnatomymusculoskeletal systemBiomechanical PhenomenaCalcaneusmedicine.anatomical_structureCattleFemaleCortical boneTomographyCalcaneusBody mass indexMathematicsTomography Emission-ComputedJournal of Bone and Mineral Research
researchProduct

Assessment of the tibia using ultrasonic guided waves in pubertal girls

2002

The purpose of this study was to compare low frequency ultrasonic guided wave measurements with established ultrasound and bone density measurements in terms of their ability to characterize the tibia in pubertal girls. Subjects were 12-14-year-old girls ( n=106) who were participating in a calcium and vitamin D intervention study. A prototype low frequency pulse transmission device consisting of a uniaxial scanning mechanism and low frequency transducers orientated perpendicularly to the limb was used to measure two ultrasound velocities in the tibia. The first velocity, V1, was that of the first arriving signal, similar to that measured by existing commercial tibial ultrasound devices. Th…

musculoskeletal diseasesAdolescentBone densityEndocrinology Diabetes and MetabolismOsteoporosisBone DensitymedicineHumansUltrasonicsTibiaChildGuided wave testingTibiabusiness.industryBody WeightPubertyUltrasoundAnatomymusculoskeletal systemmedicine.diseaseBody HeightCalcaneusRadiusmedicine.anatomical_structureRegression AnalysisFemaleCortical boneUltrasonic sensorCalcaneusTomography X-Ray ComputedbusinessBiomedical engineeringOsteoporosis International
researchProduct

Predicting the failure in distal femur fractures.

2018

Abstract Introduction The incidence of nonunion after fractures of the distal femur is up to 6%. The distal femoral nonunion is a disabling disease that needs complex steps in his treatment. Aim of our study is to find predicting factors of non-unions. Materials and methods We retrospectively analyzed 116 cases of distal femoral fractures and 20 cases of non-unions. In both surgeries we analyzed: accuracy of reduction, stability of fixation, hardware used, residual medial or lateral bone defect, use of autologous or heterologous bone grafts. Results Malreduction, particularly axial defect, associated with unbalanced fixation, and a medial cortical bone defect of greater or lesser extent wer…

AdultMaleReoperationmedicine.medical_specialtymedicine.medical_treatmentNonunionBone graftingNon union03 medical and health sciencesDistal femurFracture Fixation InternalYoung Adult0302 clinical medicinePostoperative ComplicationsmedicineHumans030212 general & internal medicineTreatment FailureRange of Motion ArticularReduction (orthopedic surgery)General Environmental ScienceFixation (histology)AgedRetrospective StudiesFracture Healing030222 orthopedicsBone Transplantationbusiness.industryMiddle AgedBone defectmedicine.diseaseSurgeryBiomechanical Phenomenasurgical procedures operativemedicine.anatomical_structureFractures UnunitedGeneral Earth and Planetary SciencesCortical boneFemalebusinessBone PlatesFemoral FracturesInjury
researchProduct

Radiographic signs associated with inferior alveolar nerve damage following lower third molar extraction

2009

The aim was to carry out a literature review of preoperative radiographic signs in orthopantomography (OPG) and computed tomography (CT) related with the risk of inferior alveolar nerve damage during the surgical extraction of lower third molar (LTM). A search was made on PubMed for literature published between the years 2000 and 2009. In the reviewed literature, radiographic signs in the OPG that indicate a relationship between the LTM and the inferior alveolar canal are considered a risk factor for nerve damage. These signs are darkening and deflection of the root, and diversion and interruption in the white line of the canal. In the majority of these studies, the routine use of CT is not…

Molarmedicine.medical_specialtyMandibular NerveRadiographyInferior alveolar nerveLesionRadiography PanoramicSurgical extractionmedicineHumansRisk factorGeneral Dentistrybusiness.industryfungirespiratory system:CIENCIAS MÉDICAS [UNESCO]White lineSurgerymedicine.anatomical_structureOtorhinolaryngologyTooth ExtractionUNESCO::CIENCIAS MÉDICASMolar ThirdTrigeminal Nerve InjuriesSurgeryCortical boneRadiologymedicine.symptomTomography X-Ray ComputedbusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct